Single-phase/two-phase/three-phase and three phase switching power supply unit

A truly complete range of switching power supplies, single-phase/two-phase/three-phase, designed for a wide variety of applications. Wide input voltages allow them to operate on all continents. They are equipped with DIN rail mounting and offer an IP20 protection rating. Extreme compactness and full compliance with the Machinery Directive 60204-1 change the way to provide power to the electrical panel.

This line of single-phase/two-phase/three-phase switching power supply units called SW was created for use in the industrial field where reliability, sturdiness and ease of use are characteristics of primary importance; this makes the products usable in different sectors.

Technical Specifications of our Single-phase/Two-phase/Three-phase Switching Power Supplies

Output Voltage:

5,12,24,48 Vdc

Output current:

– Single-phase: 2 – 3 –4 – 7.5 – 14.5 –25A

– Two-phase: 5 –7.5 –14.5A

– Three-phase: 25A

    • 3 types of short circuit/overload enabling, i.e. Hiccup Mode, Fold Back and Restart after Main

    • One product for input voltages 230-400-500Vac

    • Small dimensions.

    • Products 100% made in Italy.

    • Optimal use of power supply units is below 95% of Ampere Plate capacity.

    • Total warranty 2 years.

    • Computerized testing on each power supply and testing under real working conditions at 100% rated data.

    • The input voltage is single-phase and completely covers the range V min 90 max 260 V ac. (MY) and V. min 360 max 530 V ac (MX).

    • The output is protected against overload and short circuit, indicated by the flashing and shutting off of the DC LED, respectively.

    • The output is protected against overvoltage, and the AC LED indicates the presence of the mains voltage.

    • The metal container has an easy-to-use coupling for DIN rail mounting with earth connection.

    • It is possible to connect the negative pole (M) to ground output.

    • Connectable in series.

    • Up to 4 power supply units can be connected in parallel.

    • CE conformity.

       

 

Compact size

High levels of efficiency obtained from our power supplies, have allowed to halve the size compared to a conventional power supply.

Manual Reset

To restart the output it is necessary to turn off the primary power supply for about 1 minute and then turn it back on. This mode is particularly recommended in applications where maintenance personnel are required. Just change the position of the Jumper!

Important Benefits

Unique product in stock adaptable to any input voltage and excellent for the management of any type of output current.

Semi-resonant Switching Technology: efficiency up to 93% and continuous and instantaneous output power.

Single-phase/Two-phase/Three-phase Switching Power Supplies
Switching power supply unit 24 Vdc

Simple parallel connection on all single-phase/two-phase/three-phase switching power supplies

Simple parallel connection for double capacity with our power supplies. Up to 4 units can be connected in parallel, using a tester to balance the outputs. Just remove the jumper!

Power Good – Output voltage control

The output voltage is continuously monitored, and the NO contact changes state every time the voltage drops below 20 Vdc. This application is used in redundant systems to ensure that power is always available to critical loads.

Hiccup Mode

In the event of a short circuit or overload, the output energy is interrupted.

The device retries every about 2 sec. to restore the output energy, cyclically, until the problem is solved. Just change the position of the Jumper!

Continuos Output Mode

In case of Short circuit or overload, the output current is kept maximum even when the voltage is at zero.This function is required to satisfy heavy loads such as motors, solenoids, lamps, PLCs with strong capacitive input loads and other devices that require strong current transients. Just change the position of the Jumper!

Output protected by magnetothermic switches

The output can be disconnected easily and safely. The defective part is disconnected, the defect is limited and the important parts of the system can continue to operate. Our power supplies generate 50% more energy as per EN60204 -1 which requires safe control in all overload and short-circuit conditions; the protections must intervene .

Power Boost

This feature allows to use small sizes of power supplies to cope with high current transients (Power Boost of 150%, for not less than 3 minutes) such as motors, solenoids, lamps. Otherwise it would be necessary to oversize the units.

Datasheet and Manuals

Monophase
Code Input Output Datasheet Manuale Additional Data
SW5A5VDC 115-230Vac 5A PDF PDF PDF

Monophase
Code Input Output Datasheet Manuale Additional Data
SW4AMFL 115-230Vac
Input Selectable
4A PDF PDF PDF
SW14AMFL 115-230Vac
Input Selectable
14A PDF PDF PDF
SW16AMFL 115-230Vac
Input Selectable
16A PDF PDF PDF

Monophase
Code Input Output Datasheet Manuale Additional Data
SW2.5AMF 115-230Vac 2A(115)
3A(230)
PDF PDF PDF
SW5AMFL 115-230Vac
Input Selectable
5A PDF PDF PDF
SW7.5AMFL 115-230Vac
Input Selectable
7,5A PDF PDF PDF
SW15AMFL 115-230Vac
Input Selectable
14A PDF PDF PDF
SW25AMFL 115-230-277Vac
Input Selectable
25A PDF PDF PDF

 

Biphase and Threephase
Code Input Output Datasheet Manuale Additional Data
SW5ABF 230–400–500Vac
Input Selectable
5A PDF PDF PDF
SW7.5ABF 230–400–500Vac
Input Selectable
7.5A PDF PDF PDF
SW15ABF 230–400–500Vac
Input Selectable
15A PDF PDF PDF
SW25AF3F 400–500Vac
3xVac
25A PDF PDF PDF
Input Selectable

Monofase
Code Input Output Datasheet Manuale Additional Data
SW3.8AML 115-230Vac
Input Selectable/td>
5A PDF PDF PDF
SW7AMFL 115-230Vac
Input Selectable
7A PDF PDF PDF
SW12AMFL 115-230Vac
Input Selectable
12A PDF PDF PDF

Standard

Assembling device: IEC/EN 60950 (V DE 0805) and EN 50178 (VDE 0160). Instal lat ion accord ing: IEC/EN 60950. Input / Output separa tion: SELV EN 60950-1 and PELV EN 60204-1. Double or reinf orced insulation

EN 61000-4 -2, EN 61000-4- 3, EN 61000-4-4, EN 61000-4-5

EN 61000-6 -4, EN 61000-3-

Safety of Electrical Equipment Machines: EN 60204-

Serie Connection for a Maximum Voltage of 150 Vdc for All Our Single-Phase/Two-Phase/Three-Phase Switching Power Supplies